• Ifm Sm8000 Magnetic-Inductive Flow Meter
  • Ifm Sm8000 Magnetic-Inductive Flow Meter
  • Ifm Sm8000 Magnetic-Inductive Flow Meter
  • Ifm Sm8000 Magnetic-Inductive Flow Meter
  • Ifm Sm8000 Magnetic-Inductive Flow Meter
  • Ifm Sm8000 Magnetic-Inductive Flow Meter

Ifm Sm8000 Magnetic-Inductive Flow Meter

Task: Adjust
Structure: Combination
Mathematical Model: Linear
Signal: Discrete
Function: Automatic Control, Protection
Certification: RoHS, CCC, ISO: 9001, CE
Gold Member Since 2023

Suppliers with verified business licenses

Trading Company

Basic Info.

Model NO.
SM8000
Condition
New
Customized
Customized
Material
Stainless Steel
MOQ
1PC
Product Conditions
Brand New
Warranty
12 Months
Transport Package
Carton
Specification
Weight [g] 577
Origin
China
Production Capacity
5000PCS/Year

Product Description

IFM SM8000 Magnetic-inductive flow meter

Magnetic-inductive flow meter
Ifm Sm8000 Magnetic-Inductive Flow Meter
Ifm Sm8000 Magnetic-Inductive Flow Meter
Product characteristics
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Measuring range
0.2...100 l/min 0.01...6 m³/h
Process connection threaded connection G 1 DN25 flat seal
Application
System gold-plated contacts
Application Totalizer function; for industrial applications
Installation connection to pipe by means of an adapter
Media Conductive liquids; water; water-based media
Note on media
conductivity: ≥ 20 µS/cm
viscosity: < 70 mm²/s (40 °C)
Medium temperature [°C] -10...70
Pressure rating [bar] 16
Pressure rating [Mpa] 1.6
MAWP (for applications according to CRN) [bar] 11.2
Electrical data
Operating voltage [V] 18...30 DC; (to SELV/PELV)
Current consumption [mA] 95; (24 V)
Protection class III
Reverse polarity protection yes
Power-on delay time [s] 5
Inputs / outputs
Number of inputs and outputs Number of digital outputs: 2; Number of analog outputs: 1
Inputs
Inputs counter reset
Outputs
Total number of outputs 2
Output signal switching signal; analog signal; pulse signal; IO-Link; (configurable)
Electrical design PNP/NPN
Number of digital outputs 2
Output function normally open / closed; (configurable)
Max. voltage drop switching output DC [V] 2
Permanent current rating of switching output DC [mA] 200
Number of analog outputs 1
Analog current output [mA] 4...20; (scalable)
Max. load [Ω] 500
Analog voltage output [V] 0...10; (scalable)
Min. load resistance [Ω] 2000
Pulse output flow rate meter
Short-circuit protection yes
Type of short-circuit protection yes (non-latching)
Overload protection yes
Measuring/setting range
Measuring range
0.2...100 l/min 0.01...6 m³/h
Display range
-120...120 l/min -7.2...7.2 m³/h
Resolution
0.1 l/min 0.005 m³/h
Set point SP
0.7...100 l/min 0.04...6 m³/h
Reset point rP
0.2...99.5 l/min 0.01...5.97 m³/h
Analog start point ASP
0...80 l/min 0...4.8 m³/h
Analog end point AEP
20...100 l/min 1.2...6 m³/h
In steps of
0.1 l/min 0.005 m³/h
Volumetric flow quantity monitoring
Pulse value 0.00001...100 000 m³
Pulse length [s] 0,0025...2
Temperature monitoring
Measuring range [°C] -20...80
Resolution [°C] 0.2
Set point SP [°C] -19.2...80
Reset point rP [°C] -19.6...79.6
Analog start point [°C] -20...60
Analog end point [°C] 0...80
In steps of [°C] 0.2
Accuracy / deviations
Flow monitoring
Accuracy (in the measuring range) ± (0,8 % MW + 0,5 % MEW)
Repeatability ± 0,2% MEW
Temperature monitoring
Accuracy [K] ± 2,5 (Q > 5 l/min)
Reaction times
Flow monitoring
Response time [s] 0.15; (dAP = 0, T19)
Delay time programmable dS, dr [s] 0...50
Damping process value dAP [s] 0...5
Temperature monitoring
Dynamic response T05 / T09 [s] T09 = 20 (Q > 5 l/min)
Software / programming
Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / closed; switching logic; current/voltage/pulse output; Start-up delay; display can be deactivated; Display unit
Interfaces
Communication interface IO-Link
Transmission type COM2 (38,4 kBaud)
IO-Link revision 1.1
SDCI standard IEC 61131-9
Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
SIO mode yes
Required master port class A
Process data analog 3
Process data binary 2
Min. process cycle time [ms] 5
Supported DeviceIDs
Type of operation DeviceID
default 575
Operating conditions
Ambient temperature [°C] -10...60
Storage temperature [°C] -25...80
Protection IP 67
Tests / approvals
EMC
DIN EN 60947-5-9  
CPA approval
model number 002MI
accuracy class -
maximum allowable error ± 1,5 % FS
Q (min) 0,01 m³/h
Q (t) -
Q (max) 6 m³/h
Shock resistance
DIN IEC 68-2-27 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-6 5 g (10...2000 Hz)
MTTF [years] 145
Pressure equipment directive sound engineering practice; can be used for group 2 fluids; group 1 fluids on request
Mechanical data
Weight [g] 577
Material stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE
Materials (wetted parts) stainless steel (1.4404 / 316L); PEEK; FKM
Process connection threaded connection G 1 DN25 flat seal
Displays / operating elements
Display
Display unit 6 x LED, green (l/min, m³/h, l, m³, 10³, °C)
Switching status 2 x LED, yellow
Measured values alphanumeric display, 4-digit
Programming alphanumeric display, 4-digit
Remarks
Remarks
MW = Measured value
MEW = Final value of the measuring range
Pack quantity 1 pcs.
Electrical connection
Connection Connector: 1 x M12; coding: A; Contacts: gold-plated
 
Ifm Sm8000 Magnetic-Inductive Flow Meter
Ifm Sm8000 Magnetic-Inductive Flow Meter
Ifm Sm8000 Magnetic-Inductive Flow Meter

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now